GRE / FRP Line Pipe
Rigid composite line pipe for corrosive gathering and injection-class duties. Start with medium, design P/T, and OD before you ask for a datasheet.
Open collectionStart with RTP flowlines or GRE tubing. Explore other product families below, or send the operating conditions you have so far.
Standards buyers often compare: API 15HR vs 15LR · API 15S vs 17J · Fiberglass coupling types
Looking for a technical guide or a selection checklist? Open technical resources
Browse by product family, then review the technical details of a specific product.
Rigid composite line pipe for corrosive gathering and injection-class duties. Start with medium, design P/T, and OD before you ask for a datasheet.
Open collectionReview well conditions, internal and external pressure, loads and connection requirements for your tubing configuration.
Open collectionFiberglass casing sizes and pressure classes for projects that specify non-metallic casing strings — confirm hole size and cement plan in the RFQ.
Open collectionGRE screen tube for sand-control and completion-related fiberglass screen discussions — slot/open-area needs belong in the RFQ.
Open collectionAdhesive-bonded, double-bell, and related joint hardware — the coupler kit is part of every GRE/FRP string RFQ.
Open collectionStart with the fluid, pressure, temperature, route and installation requirements for a spoolable piping review.
Open collectionFRP/GRP storage tanks — capacity, diameter, medium, and site code drive the RFQ more than brochure adjectives.
Open collectionDouble-wall FRP tank constructions when secondary containment is part of the project brief.
Open collectionElbows, tees, reducers, and related FRP/GRE fittings — match resin system and pressure class to the pipe family.
Open collectionContinuous fiberglass and carbon-fiber sucker rod options — well depth, load, and corrosion drive selection.
Open collectionSurface piping system scope — when the RFQ is a routed system, not a single stick of pipe.
Open collectionBMC and other moulded fiberglass components — drawing-driven RFQs beat catalog adjectives.
Open collection
Request this fiberglass tube using the 2-7/8 in. 2500 PSI catalogue designation. Confirm the dimensional basis, connection and applicable pressure-temperature conditions against the offered drawing and datasheet.
View product & technical details
Adhesive-bonded joints for compatible fiberglass pipe components. Confirm the joint geometry, adhesive system, service conditions and assembly requirements before selecting the connection.
View product & technical details
Aerogel-modified fire retardant coating for insulation, flame retardancy and surface protection. Confirm grade and coverage on RFQ.

GRE tubing enquiries referencing API 15HR require confirmation of the intended service and applicable product specification. Submit the well or pipeline conditions and connection drawing for review of the offered configuration.

For enquiries referencing API 15LR, identify whether the requirement is for a surface line or a well application. Request the applicable specification, dimensions and rating for the proposed pipe-and-joint assembly.
View product & technical details
Parking-space fire control device with smoke, heat and video detection that auto-deploys a high-silica containment blanket. Confirm layout on RFQ.

AI concept illustration
BMC moulded components manufactured to an agreed drawing. Specify part geometry, material requirements, finish, tolerances and quantity for review of the moulding scope.
View product & technical details
Double-bell coupler joints for compatible fiberglass pipe ends. Specify dimensions, service conditions and pipeline layout to confirm the seals, movement limits and thrust-management arrangement.
View product & technical details
Fiberglass-reinforced epoxy tube supplied to an agreed dimensional and connection specification. Identify the catalogue configuration and provide the service conditions to confirm the offered drawing and pressure-temperature rating.
View product & technical details
FF double-wall composite tanks for project-specific storage installations. Define the stored medium, capacity, site conditions and interstitial monitoring requirements to request a matched tank proposal.

Continuous composite sucker rod for a specified pumping system. Confirm the reinforcement material, rod dimensions, operating loads and installation equipment before selecting a configuration.
View product & technical details
Fiberglass casing for project-specific well installations. Provide well depth, dimensions, fluid conditions, external loads and connection details to confirm the casing design and supporting documentation.
Send your product requirements, quantities and destination. Our team can help you identify the technical information you need.