- Description
- Specifications
- Up to 1,400 mm, Pressure up to 50 bar.
- Non-Restrained Joint, with flexibility and deflection, requires thrust blocks or hybrid systems.
- Typically used in buried applications. Hydropower applications may utilize aboveground installation.
On IFGS GRE/FRP line pipe, a rubber-seal bell-and-spigot joint seats the spigot in a belled end with an elastomeric seal. Published catalog envelope: up to 1,400 mm and up to 50 bar; non-restrained designs need thrust blocks or hybrid systems; typical use is buried. This page is the RFQ landing for that joint family—use it to confirm envelope, restraint choice, and what to send before you request a datasheet or quotation from Dongying.
Specs & envelope
| Attribute | Published on this product |
|---|---|
| Size / pressure | Up to 1,400 mm; pressure up to 50 bar |
| Restraint | Non-restrained; flexibility and deflection |
| Thrust management | Requires thrust blocks or hybrid systems |
| Typical installation | Buried; hydropower may use aboveground |
| Sister product | Rubber Seal Bell And Spigot Locked Joint (restrained; does not require thrust blocks; same published size/pressure headline) |
Choose the locked sister when you need restraint without thrust blocks; same published size/pressure headline.
Where it fits
IFGS manufactures GRE and FRP pipe systems in Dongying for oilfield and geothermal service, and positions fiberglass where steel corrodes—produced water, injection, and chemical lines. On those strings, a rubber-seal bell-and-spigot joint is the option when you want buried-line flexibility with a sealed push-fit style connection rather than a threaded or laminated joint family.
RFQ checklist
Before you request a quotation, include:
- Joint type you intend — non-restrained rubber-seal bell & spigot, or locked/restrained; say if you still need help choosing.
- Diameter and pressure class — stay inside the published envelope (up to 1,400 mm / up to 50 bar) or flag if your duty is outside it.
- Service and fluid — oilfield / industrial; produced water, injection, chemical, or other corrosive duty.
- Installation — buried vs aboveground; note hydropower or aboveground segments explicitly.
- Thrust plan — thrust blocks, hybrid systems, or “prefer no thrust blocks” (points you toward locked).
- Standards you will audit against — ask for the joint datasheet that aligns with your pipe standard set (IFGS references API Spec 15HR / 15LR on related line-pipe and standards pages).
- Quantity, length schedule, fittings, and delivery window.
Ask for the product datasheet by name—not only a unit price. Verified technical data is available on request.
FAQ
What does “spigot joint” mean for a fiberglass line-pipe RFQ?
For a GRE/FRP inquiry, a spigot joint usually means a rubber-seal bell-and-spigot connection: the spigot end enters a bell sealed with elastomer. On IFGS pages, this family is listed up to 1,400 mm and up to 50 bar, mainly for buried service. Name non-restrained vs locked in the RFQ so thrust design and civil scope are priced correctly.
Do you need thrust blocks with this joint?
Yes for the non-restrained option: IFGS states that the joint requires thrust blocks or hybrid systems. If your project cannot carry that civil cost, evaluate the locked sister joint, which is restrained and does not require thrust blocks.
Is the locked sister the same size and pressure range?
Yes on the published catalog lines: both list up to 1,400 mm and pressure up to 50 bar. The real decision is restraint and thrust-block policy. Ask for verified datasheets if your duty sits near those limits.
Can this joint be used aboveground?
Typical use is buried. The non-restrained product page also notes that hydropower applications may utilize aboveground installation. Call aboveground runs out in the RFQ.
What should you attach when asking IFGS for a quotation?
Diameter, pressure class, fluid/service, buried vs aboveground, restrained vs non-restrained preference, thrust-block constraints, standards you will audit, and a length/quantity schedule—plus an explicit datasheet request.
For a longer decision walk-through, see the spigot joint RFQ guide. Ready to quote? Contact IFGS or use Request a quote on this page.
A technical datasheet is not published on this page. Request the applicable dimensions, ratings and supporting documents for your project. Request the product datasheet.
Let’s discuss your project
Send your product requirements, quantities and destination. Our team can help you identify the technical information you need.